| Assessment Year | 2009 |
|---|---|
| Principal Product | Countertops |
| NAICS | 337110: Wood Kitchen Cabinet and Countertop Manufacturing |
| SIC | 2434: Wood Kitchen Cabinets |
| Sales Range | $10 M to 50M |
| # of Employees | 46 |
| Plant Area |
70,000
ft2
|
| Annual Production | 3,850
thousand feet
|
| Production Hrs. Annual | 2,268
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $196,045 | 2,310,376 |
kWh
|
$0.085 |
| Natural Gas | $12,350 | 1,191 |
MMBtu
|
$10.37 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $50,875 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $43,765 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,930 | $21,500 |
$18,140
197,200
kWh
|
- | - | $790 | |
| 02 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $15,000 | $25,000 | - | - | $15,000 | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,720 | $1,000 |
$7,720
83,900
kWh
|
- | - | - | |
| 04 | 2.7145: Install skylights | $6,040 | $22,100 |
$6,040
65,700
kWh
|
- | - | - | |
| 05 | 2.8121: Apply for tax-free status for energy purchases | $1,070 | - | - | - | $1,070 | - | |
| 06 | 2.6218: Turn off equipment when not in use | $715 | - |
$715
7,780
kWh
|
- | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $690 | $305 |
$180
1,935
kWh
|
$510 | - | - | |
| 08 | 2.7124: Make a practice of turning off lights when not needed | $450 | - |
$450
4,910
kWh
|
- | - | - | |
| 09 | 2.4314: Use synthetic lubricant | $260 | - |
$260
2,835
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $50,875 | $69,905 |
$33,505
364,260
kWh
|
$510 | $16,070 | $790 | ||
| TOTAL IMPLEMENTED | $43,765 | $47,805 |
$27,465
298,560
kWh
|
$510 | $15,000 | $790 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs