| Assessment Year | 2009 |
|---|---|
| Principal Product | metal and fiber drums |
| NAICS | 332439: Other Metal Container Manufacturing |
| SIC | 3412: Metal Shipping Barrels, Drums, Kegs, and Pails |
| Sales Range | $10 M to 50M |
| # of Employees | 112 |
| Plant Area |
180,000
ft2
|
| Annual Production | 2,064,000
pieces
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $455,969 | 5,705,697 |
kWh
|
$0.080 |
| Electricity Demand | $117,825 | 17,037 |
kW-mo/yr
|
$6.92 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $83,274 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $75,174 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $59,900 | $3,000 |
$48,000
565,000
kWh
|
$11,900
-
kW-mo/yr
|
- | - | - | |
| 02 | 3.6192: Use a less expensive method of waste removal | $6,000 | $37,000 | - | - | - |
$6,000
-
Tgal
|
- | |
| 03 | 2.6218: Turn off equipment when not in use | $5,055 | - |
$365
4,300
kWh
|
- | - | - | $4,690 | |
| 04 | 2.4133: Use most efficient type of electric motors | $3,585 | - |
$2,615
30,500
kWh
|
$970
-
kW-mo/yr
|
- | - | - | |
| 05 | 3.6192: Use a less expensive method of waste removal | $2,100 | - | - | - | - |
$2,100
-
Tgal
|
- | |
| 06 | 2.4314: Use synthetic lubricant | $1,565 | - |
$1,180
13,900
kWh
|
$385
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.7124: Make a practice of turning off lights when not needed | $930 | $280 |
$730
8,600
kWh
|
$200
-
kW-mo/yr
|
- | - | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $740 | $360 |
$170
1,960
kWh
|
$20
-
kW-mo/yr
|
- | - | $550 | |
| 09 | 2.7124: Make a practice of turning off lights when not needed | $865 | $500 |
$715
8,415
kWh
|
$150
-
kW-mo/yr
|
- | - | - | |
| 10 | 2.8123: Pay utility bills on time | $2,534 | - | - | - | $2,534 | - | - | |
| TOTAL RECOMMENDED | $83,274 | $41,140 |
$53,775
632,675
kWh
|
$13,625
-
kW-mo/yr
|
$2,534 |
$8,100
-
Tgal
|
$5,240 | ||
| TOTAL IMPLEMENTED | $75,174 | $4,140 |
$53,775
632,675
kWh
|
$13,625
-
kW-mo/yr
|
$2,534 | - | $5,240 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Disposal Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs