Assessment Year | 2009 |
---|---|
Principal Product | Aluminum junction boxes |
NAICS | 332322: Sheet Metal Work Manufacturing |
SIC | 3644: Noncurrent-Carrying Wiring Devices |
Sales Range | $10 M to 50M |
# of Employees | 170 |
Plant Area |
82,150
ft2
|
Annual Production | 2,160,000
lb
|
Production Hrs. Annual | 7,248
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $286,570 | 2,940,576 |
kWh
|
$0.097 |
Electricity Demand | $70,046 | 11,372 |
kW-mo/yr
|
$6.16 |
Natural Gas | $119,316 | 11,892 |
MMBtu
|
$10.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $178,470 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $51,470 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1321: Replace fossil fuel equipment with electrical equipment | $110,800 | $325,000 |
$(-39,500.0)
(-379,800)
kWh
|
$(-4,500.0)
-
kW-mo/yr
|
$98,400
-
MMBtu
|
$56,400 | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $27,000 | $36,100 |
$23,800
229,200
kWh
|
$3,200
-
kW-mo/yr
|
- | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,800 | $1,000 |
$12,600
121,000
kWh
|
$1,200
-
kW-mo/yr
|
- | - | - | |
04 | 2.3212: Optimize plant power factor | $6,510 | $21,230 | - |
$6,510
-
kW-mo/yr
|
- | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $5,650 | $11,713 |
$5,109
49,121
kWh
|
$541
-
kW-mo/yr
|
- | - | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $4,980 | $3,900 |
$3,100
29,740
kWh
|
$1,880
-
kW-mo/yr
|
- | - | - | |
07 | 2.7145: Install skylights | $3,200 | $4,140 |
$3,200
30,700
kWh
|
- | - | - | - | |
08 | 2.7124: Make a practice of turning off lights when not needed | $3,290 | $1,000 |
$3,040
29,200
kWh
|
$250
-
kW-mo/yr
|
- | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,730 | $8,200 |
$1,800
17,370
kWh
|
- | - | - | $(-70.0) | |
10 | 2.4314: Use synthetic lubricant | $1,405 | - |
$1,270
12,200
kWh
|
$135
-
kW-mo/yr
|
- | - | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $105 | $82 |
$33
315
kWh
|
$3
-
kW-mo/yr
|
- | - | $69 | |
TOTAL RECOMMENDED | $178,470 | $412,365 |
$14,452
139,046
kWh
|
$9,219
-
kW-mo/yr
|
$98,400
-
MMBtu
|
$56,400 | $(-1.0) | ||
TOTAL IMPLEMENTED | $51,470 | $58,013 |
$46,349
445,891
kWh
|
$5,191
-
kW-mo/yr
|
- | - | $(-70.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |