Assessment Year | 2008 |
---|---|
Principal Product | buns and muffins |
NAICS | 311812: Commercial Bakeries |
SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
Sales Range | $50 M to 100M |
# of Employees | 111 |
Plant Area |
60,000
ft2
|
Annual Production | 10,555,320
pieces
|
Production Hrs. Annual | 8,012
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $410,161 | 8,730,720 |
kWh
|
$0.047 |
Electricity Demand | $164,773 | 14,083 |
kW-mo/yr
|
$11.70 |
Natural Gas | $447,470 | 62,160 |
MMBtu
|
$7.20 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $93,540 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $90,760 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $42,500 | $1,550 |
$32,500
570,000
kWh
|
$10,000
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,950 | $32,300 |
$14,500
254,400
kWh
|
$4,450
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $13,330 | $12,480 |
$9,830
172,500
kWh
|
$3,500
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.8118: Check for accuracy of utility / power meters | $6,600 | $5,000 | - | - | - | - | - |
$6,600
-
Tgal
|
|
05 | 3.7121: Improve handling practices | $5,090 | $110 | - | - | - | $5,090 | - | - | |
06 | 2.7124: Make a practice of turning off lights when not needed | $3,800 | $1,000 |
$2,940
51,530
kWh
|
$860
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.4314: Use synthetic lubricant | $2,200 | - |
$1,670
29,300
kWh
|
$530
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.2511: Insulate bare equipment | $580 | $90 | - | - |
$580
-
MMBtu
|
- | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $490 | $380 |
$85
1,470
kWh
|
$20
-
kW-mo/yr
|
- | - | $385 | - | |
TOTAL RECOMMENDED | $93,540 | $52,910 |
$61,525
1,079,200
kWh
|
$19,360
-
kW-mo/yr
|
$580
-
MMBtu
|
$5,090 | $385 |
$6,600
-
Tgal
|
||
TOTAL IMPLEMENTED | $90,760 | $52,820 |
$59,855
1,049,900
kWh
|
$18,830
-
kW-mo/yr
|
- | $5,090 | $385 |
$6,600
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs