Assessment Year | 2008 |
---|---|
Principal Product | Metal drums |
NAICS | 332439: Other Metal Container Manufacturing |
SIC | 3412: Metal Shipping Barrels, Drums, Kegs, and Pails |
Sales Range | $10 M to 50M |
# of Employees | 54 |
Plant Area |
100,000
ft2
|
Annual Production | 25,000,000
pieces
|
Production Hrs. Annual | 7,248
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $460,870 | 5,496,819 |
kWh
|
$0.084 |
Electricity Demand | $69,775 | 13,803 |
kW-mo/yr
|
$5.06 |
Electricity Fees | $56,255 | - |
|
- |
Natural Gas | $620,232 | 82,986 |
MMBtu
|
$7.47 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $306,470 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $290,150 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $68,500 | $45,600 |
$63,500
628,000
kWh
|
$5,000
-
kW-mo/yr
|
- | - | - | - | - | |
02 | 4.212: Adopt in-house material generation | $29,390 | $77,000 |
$(-12,400.0)
(-126,800)
kWh
|
$(-1,010.0)
-
kW-mo/yr
|
- | - | - | $42,800 | - | |
03 | 2.8121: Apply for tax-free status for energy purchases | $178,620 | $5,000 | - | - | - | - | $35,720 | - | $142,900 | |
04 | 2.7145: Install skylights | $15,220 | $30,900 |
$15,220
155,500
kWh
|
- | - | - | - | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,790 | $350 |
$4,350
44,400
kWh
|
$440
-
kW-mo/yr
|
- | - | - | - | - | |
06 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $4,750 | - |
$4,310
44,040
kWh
|
$440
-
kW-mo/yr
|
- | - | - | - | - | |
07 | 2.4314: Use synthetic lubricant | $2,870 | - |
$2,670
27,300
kWh
|
$200
-
kW-mo/yr
|
- | - | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,230 | $325 |
$290
2,940
kWh
|
$25
-
kW-mo/yr
|
- | $915 | - | - | - | |
09 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $1,100 | $6,700 | - | - |
$1,100
-
lb
|
- | - | - | - | |
TOTAL RECOMMENDED | $306,470 | $165,875 |
$77,940
775,380
kWh
|
$5,095
-
kW-mo/yr
|
$1,100
-
lb
|
$915 | $35,720 | $42,800 | $142,900 | ||
TOTAL IMPLEMENTED | $290,150 | $128,275 |
$62,720
619,880
kWh
|
$5,095
-
kW-mo/yr
|
- | $915 | $35,720 | $42,800 | $142,900 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs