| Assessment Year | 2008 |
|---|---|
| Principal Product | Envelopes |
| NAICS | 322230: Stationery Product Manufacturing |
| SIC | 2677: Envelopes |
| Sales Range | $10 M to 50M |
| # of Employees | 145 |
| Plant Area |
114,702
ft2
|
| Annual Production | 2,167,000,000
pieces
|
| Production Hrs. Annual | 8,496
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $653,326 | 8,466,418 |
kWh
|
$0.077 |
| Electricity Demand | $113,500 | 16,629 |
kW-mo/yr
|
$6.83 |
| Electricity Fees | $12,050 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $90,670 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $90,670 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $27,200 | $42,370 |
$24,050
316,400
kWh
|
$3,150
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $26,350 | $2,500 |
$23,300
306,600
kWh
|
$3,050
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.7124: Make a practice of turning off lights when not needed | $16,810 | - |
$14,140
186,100
kWh
|
$2,670
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.7232: Replace existing hvac unit with high efficiency model | $10,200 | $24,000 |
$10,200
134,000
kWh
|
- | - | - | - | |
| 05 | 2.8123: Pay utility bills on time | $6,800 | - | - | - | $6,800 | - | - | |
| 06 | 2.4314: Use synthetic lubricant | $1,885 | - |
$1,670
21,915
kWh
|
$215
-
kW-mo/yr
|
- | - | - | |
| 07 | 3.7132: Reuse rags until completely soiled | $1,040 | - | - | - | - | - | $1,040 | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $385 | - |
$75
980
kWh
|
$5
-
kW-mo/yr
|
- | $305 | - | |
| TOTAL RECOMMENDED | $90,670 | $68,870 |
$73,435
965,995
kWh
|
$9,090
-
kW-mo/yr
|
$6,800 | $305 | $1,040 | ||
| TOTAL IMPLEMENTED | $90,670 | $68,870 |
$73,435
965,995
kWh
|
$9,090
-
kW-mo/yr
|
$6,800 | $305 | $1,040 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs