| Assessment Year | 2006 |
|---|---|
| Principal Product | Oil field specialty chemicals |
| NAICS | 325180: Other Basic Inorganic Chemical Manufacturing |
| SIC | 2819: Industrial Inorganic Chemicals, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 35 |
| Plant Area |
50,000
ft2
|
| Annual Production | 32,000,000
lb
|
| Production Hrs. Annual | 3,980
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $96,567 | 1,379,400 |
kWh
|
$0.070 |
| Electricity Demand | $17,400 | 4,920 |
kW-mo/yr
|
$3.54 |
| Electricity Fees | $55 | - |
|
- |
| Natural Gas | $210,351 | 19,917 |
MMBtu
|
$10.56 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $74,820 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $74,147 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $7,530 | $500 | - |
$7,530
-
MMBtu
|
- | - | |
| 02 | 2.8121: Apply for tax-free status for energy purchases | $31,494 | $12,000 | - | - | $6,294 | $25,200 | |
| 03 | 2.8121: Apply for tax-free status for energy purchases | $30,123 | $12,050 | - | - | $6,023 | $24,100 | |
| 04 | 2.2135: Repair and eliminate steam leaks | $4,570 | $1,000 | - |
$4,570
-
MMBtu
|
- | - | |
| 05 | 2.8123: Pay utility bills on time | $673 | - | - | - | $673 | - | |
| 06 | 2.7124: Make a practice of turning off lights when not needed | $430 | - |
$430
8,470
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $74,820 | $25,550 |
$430
8,470
kWh
|
$12,100
-
MMBtu
|
$12,990 | $49,300 | ||
| TOTAL IMPLEMENTED | $74,147 | $25,550 |
$430
8,470
kWh
|
$12,100
-
MMBtu
|
$12,317 | $49,300 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs