Assessment Year 2006
Principal Product Plug valves, pipeline closures
NAICS 332919: Other Metal Valve and Pipe Fitting Manufacturing
SIC 3494: Valves and Pipe Fittings, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 50
Plant Area 71,900
ft2
Annual Production 38,000
pieces
Production Hrs. Annual 5,781
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $106,607 1,807,104
kWh
Electricity Fees $20,708 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $11,980 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,180

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $1,340 $1,125 $2,900
49,100
kWh
- - $(-1,560.0)
02 4.211: Consider use / purchase of bulk materials where possible $2,560 $1,640 - $2,490 - $70
03 2.8121: Apply for tax-free status for energy purchases $2,270 - - - $2,270 -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,910 $1,000 $1,910
32,000
kWh
- - -
05 2.7145: Install skylights $1,170 $2,140 $1,550
26,000
kWh
$(-380.0) - -
06 2.4239: Eliminate or reduce compressed air usage $1,360 $470 $1,360
22,750
kWh
- - -
07 2.4314: Use synthetic lubricant $1,000 - $1,000
17,250
kWh
- - -
08 2.7124: Make a practice of turning off lights when not needed $370 - $370
6,200
kWh
- - -
TOTAL RECOMMENDED $11,980 $6,375 $9,090
153,300
kWh
$2,110 $2,270 $(-1,490.0)
TOTAL IMPLEMENTED $4,180 $1,000 $1,910
32,000
kWh
- $2,270 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs