Assessment Year | 2004 |
---|---|
Principal Product | Valve repair and coating |
NAICS | 332911: Industrial Valve Manufacturing |
SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
159,800
ft2
|
Annual Production | 15,000
pieces
|
Production Hrs. Annual | 5,184
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $203,882 | 3,328,526 |
kWh
|
$0.061 |
Electricity Demand | $55,812 | 966 |
kW-mo/yr
|
$57.78 |
Electricity Fees | $8,318 | - |
|
- |
Natural Gas | $73,376 | 7,649 |
MMBtu
|
$9.59 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,725 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $39,850 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7124: Make a practice of turning off lights when not needed | $6,920 | $1,930 |
$5,360
92,240
kWh
|
$1,560
-
kW-mo/yr
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,740 | $680 |
$5,750
98,900
kWh
|
$990
-
kW-mo/yr
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,745 | $14 |
$1,365
23,500
kWh
|
$380
-
kW-mo/yr
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $415 | $335 |
$325
5,600
kWh
|
$90
-
kW-mo/yr
|
- | - | - | |
05 | 2.7124: Make a practice of turning off lights when not needed | $275 | $50 |
$225
3,860
kWh
|
$50
-
kW-mo/yr
|
- | - | - | |
06 | 2.8121: Apply for tax-free status for energy purchases | $25,200 | $2,600 | - | - | $5,200 | - | $20,000 | |
07 | 2.8115: Base utility charges on usage rather than area occupied | $2,130 | $18,000 | - | - | $2,130 | - | - | |
08 | 3.7132: Reuse rags until completely soiled | $300 | - | - | - | - | $300 | - | |
TOTAL RECOMMENDED | $43,725 | $23,609 |
$13,025
224,100
kWh
|
$3,070
-
kW-mo/yr
|
$7,330 | $300 | $20,000 | ||
TOTAL IMPLEMENTED | $39,850 | $5,595 |
$11,660
200,600
kWh
|
$2,690
-
kW-mo/yr
|
$5,200 | $300 | $20,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs