ITAC Assessment: AM0476
ITAC logo
ITAC Assessment: AM0476
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2004
Principal Product Ships, boats, and marine equipment
NAICS 336612: Boat Building
SIC 3732: Boat Building and Repairing
Sales Range $5
M
to 10
M
# of Employees 80
Plant Area 350,000
ft2
Annual Production 220
pieces
Production Hrs. Annual 4,318
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $140,491 1,685,608
kWh
Electricity Demand $10,201 3,717
kW-mo/yr
Electricity Fees $27,574 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $26,800 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
01 2.3212: Optimize plant power factor $13,700 $23,400 n/a - $13,700
-
kW-mo/yr
-
02 2.3212: Optimize plant power factor $2,900 $8,300 n/a - $2,900
-
kW-mo/yr
-
03 2.7124: Make a practice of turning off lights when not needed $2,530 $90 n/a $2,100
24,700
kWh
$430
-
kW-mo/yr
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,120 $500 n/a $1,900
22,000
kWh
$220
-
kW-mo/yr
-
05 2.6212: Turn off equipment during breaks, reduce operating time $350 - n/a $350
4,000
kWh
- -
06 2.8121: Apply for tax-free status for energy purchases $5,200 - n/a - - $5,200
TOTAL RECOMMENDED $26,800 $32,290 $4,350
50,700
kWh
$17,250
-
kW-mo/yr
$5,200
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs