Assessment Year 2004
Principal Product Plastic injection products
NAICS 333511: Industrial Mold Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 221
Plant Area 62,800
ft2
Annual Production 44,000,000
pieces
Production Hrs. Annual 6,144
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $374,341 5,530,530
kWh
Electricity Demand $41,637 18,885
kW-mo/yr
Electricity Fees $3,912 -
Natural Gas $4,190 520
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $32,030 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $31,595

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
01 2.2511: Insulate bare equipment $11,900 $2,160 $11,900
189,000
kWh
- - -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,900 $450 $6,900
110,000
kWh
- - -
03 2.8123: Pay utility bills on time $6,075 - - - $6,075 -
04 2.6218: Turn off equipment when not in use $3,170 - $3,170
50,300
kWh
- - -
05 2.4231: Reduce the pressure of compressed air to the minimum required $2,000 $6 $2,000
32,300
kWh
- - -
06 3.7132: Reuse rags until completely soiled $700 - - - - $700
07 2.7124: Make a practice of turning off lights when not needed $435 - $435
6,935
kWh
- - -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $420 $175 $80
1,230
kWh
$205 - $135
09 2.4314: Use synthetic lubricant $240 - $240
3,770
kWh
- - -
10 2.8112: Combine utility meters $190 - - - $190 -
TOTAL RECOMMENDED $32,030 $2,791 $24,725
393,535
kWh
$205 $6,265 $835
TOTAL IMPLEMENTED $31,595 $2,791 $24,290
386,600
kWh
$205 $6,265 $835
Yearly Savings* Imp'd Cost* Electricity Usage Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs