Assessment Year | 2004 |
---|---|
Principal Product | Metal buildings |
NAICS | 332311: Prefabricated Metal Building and Component Manufacturing |
SIC | 3448: Prefabricated Metal Buildings and Components |
Sales Range | $50 M to 100M |
# of Employees | 300 |
Plant Area |
64,000
ft2
|
Annual Production | 18,200,000
lb
|
Production Hrs. Annual | 6,060
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $136,482 | 2,126,688 |
kWh
|
$0.064 |
Electricity Demand | $25,850 | 8,280 |
kW-mo/yr
|
$3.12 |
Electricity Fees | $554 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $54,020 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $49,720 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8123: Pay utility bills on time | $26,800 | $6,700 | - | - | $13,400 | $13,400 | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,320 | $2,000 |
$13,320
218,410
kWh
|
- | - | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $3,200 | $1,400 |
$2,500
41,000
kWh
|
$700
-
kW-mo/yr
|
- | - | |
04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $3,060 | - |
$3,060
50,100
kWh
|
- | - | - | |
05 | 2.7145: Install skylights | $2,670 | $6,600 |
$2,670
43,800
kWh
|
- | - | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,630 | $45 |
$1,440
23,590
kWh
|
$190
-
kW-mo/yr
|
- | - | |
07 | 2.7145: Install skylights | $1,330 | $2,500 |
$1,330
21,900
kWh
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,050 | $770 |
$400
6,660
kWh
|
$30
-
kW-mo/yr
|
$620 | - | |
09 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $760 | - |
$760
12,500
kWh
|
- | - | - | |
10 | 2.7124: Make a practice of turning off lights when not needed | $200 | - |
$160
2,600
kWh
|
$40
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $54,020 | $20,015 |
$25,640
420,560
kWh
|
$960
-
kW-mo/yr
|
$14,020 | $13,400 | ||
TOTAL IMPLEMENTED | $49,720 | $13,370 |
$21,530
353,170
kWh
|
$770
-
kW-mo/yr
|
$14,020 | $13,400 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs