| Assessment Year | 2004 |
|---|---|
| Principal Product | Mushroom processing |
| NAICS | 311421: Fruit and Vegetable Canning |
| SIC | 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies |
| Sales Range | $10 M to 50M |
| # of Employees | 550 |
| Plant Area |
275,000
ft2
|
| Annual Production | 31,200,000
lb
|
| Production Hrs. Annual | 3,640
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $955,118 | 26,355,866 |
kWh
|
$0.036 |
| Electricity Demand | $362,541 | 46,638 |
kW-mo/yr
|
$7.77 |
| Natural Gas | $421,606 | 131,215 |
MMBtu
|
$3.21 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $36,420 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $32,920 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2136: Install / repair insulation on steam lines | $16,000 | $16,900 | - | - |
$16,000
-
MMBtu
|
|
| 02 | 2.2135: Repair and eliminate steam leaks | $7,100 | $500 | - | - |
$7,100
-
MMBtu
|
|
| 03 | 2.2113: Repair or replace steam traps | $6,850 | $400 | - | - |
$6,850
-
MMBtu
|
|
| 04 | 2.4239: Eliminate or reduce compressed air usage | $1,880 | $1,010 |
$1,880
46,750
kWh
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,870 | $400 |
$1,130
27,960
kWh
|
$740
-
kW-mo/yr
|
- | |
| 06 | 2.2135: Repair and eliminate steam leaks | $1,100 | $4,950 | - | - |
$1,100
-
MMBtu
|
|
| 07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $830 | $15 |
$500
12,400
kWh
|
$330
-
kW-mo/yr
|
- | |
| 08 | 2.2511: Insulate bare equipment | $790 | $230 | - | - |
$790
-
MMBtu
|
|
| TOTAL RECOMMENDED | $36,420 | $24,405 |
$3,510
87,110
kWh
|
$1,070
-
kW-mo/yr
|
$31,840
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $32,920 | $23,150 |
$1,130
27,960
kWh
|
$740
-
kW-mo/yr
|
$31,050
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs