Assessment Year 2004
Principal Product Industrial and agricultural mowing equipment
NAICS 333112: Lawn and Garden Tractor and Home Lawn and Garden Equipment Manufacturing
SIC 3524: Lawn and Garden Tractors and Home Lawn and Garden Equipment
Sales Range $50
M
to 100
M
# of Employees 150
Plant Area 275,000
ft2
Annual Production 2,640
pieces
Production Hrs. Annual 2,228
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $132,340 2,471,665
kWh
Electricity Fees $6,000 -
Natural Gas $64,338 8,420
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $147,978 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,528

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Solid Waste (non-haz) Savings Administrative Changes Savings Ancillary Material Cost Savings
01 3.2123: Convert to high volume low pressure (hvlp) paint guns $141,300 $680 - - $44,200
-
lb
- $97,100
02 3.7132: Reuse rags until completely soiled $1,800 - - - - - $1,800
03 2.2414: Use waste heat from hot flue gases to preheat $3,350 $14,400 - $3,350
-
MMBtu
- - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $680 $1,500 $680
12,500
kWh
- - - -
05 2.8112: Combine utility meters $528 - - - - $528 -
06 2.6218: Turn off equipment when not in use $200 - $200
3,700
kWh
- - - -
07 2.7124: Make a practice of turning off lights when not needed $120 $74 $120
2,270
kWh
- - - -
TOTAL RECOMMENDED $147,978 $16,654 $1,000
18,470
kWh
$3,350
-
MMBtu
$44,200
-
lb
$528 $98,900
TOTAL IMPLEMENTED $1,528 $1,574 $1,000
18,470
kWh
- - $528 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Solid Waste (non-haz) Savings Administrative Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs