Assessment Year 2003
Principal Product Mattress pads, carpet pads, furniture pads
NAICS 314120: Curtain and Linen Mills
SIC 2393: Textile Bags
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area 99,000
ft2
Annual Production 18,500,000
lb
Production Hrs. Annual 7,392
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $171,559 16,063
kWh
Natural Gas $291,054 42,623
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $273,214 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $140,634

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings Ancillary Material Cost Savings Primary Product Savings
01 4.652: Replace existing equipment with more suitable substitutes $120,000 $3,700 - - - $120,000
02 4.122: Develop standard procedures to improve internal yields $67,000 $100,000 - - - $67,000
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $11,400 $500 $11,400
278,000
kWh
- - -
04 4.122: Develop standard procedures to improve internal yields $13,600 $2,300 - - - $13,600
05 2.7224: Reduce space conditioning during non-working hours $7,840 - $7,840
198,500
kWh
- - -
06 4.431: Train operators for maximum operating efficiency $4,740 - - $4,740 - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $4,600 $21,200 $3,400
81,000
kWh
- $1,200 -
08 2.7124: Make a practice of turning off lights when not needed $980 - $980
23,850
kWh
- - -
09 2.4133: Use most efficient type of electric motors $43,054 $139,284 $43,054
1,069,982
kWh
- - -
TOTAL RECOMMENDED $273,214 $266,984 $66,674
1,651,332
kWh
$4,740 $1,200 $200,600
TOTAL IMPLEMENTED $140,634 $263,284 $58,834
1,452,832
kWh
- $1,200 $80,600
Yearly Savings* Imp'd Cost* Electricity Usage Savings Administrative Changes Savings Ancillary Material Cost Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs