Assessment Year | 2002 |
---|---|
Principal Product | Electroplating |
NAICS | 332813: Electroplating, Plating, Polishing, Anodizing, and Coloring |
SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
Sales Range | $5 M to 10M |
# of Employees | 68 |
Plant Area |
17,900
ft2
|
Annual Production | 365,000
pieces
|
Production Hrs. Annual | 4,630
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $64,536 | 918,774 |
kWh
|
$0.070 |
Electricity Demand | $8,822 | 3,507 |
kW-mo/yr
|
$2.52 |
Electricity Fees | $1,334 | - |
|
- |
Natural Gas | $543 | 8 |
MMBtu
|
$67.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,220 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,220 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|
01 | 4.132: Purchase new equipment to reduce material use / cost | $11,250 | $500 | - | - | $11,250 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,400 | $820 |
$260
5,400
kWh
|
$2,140 | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $570 | $60 |
$570
11,625
kWh
|
- | - | |
04 | 2.7124: Make a practice of turning off lights when not needed | $400 | - |
$400
8,150
kWh
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $330 | $60 |
$330
6,730
kWh
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $170 | $50 |
$170
3,500
kWh
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $100 | $50 |
$100
2,300
kWh
|
- | - | |
TOTAL RECOMMENDED | $15,220 | $1,540 |
$1,830
37,705
kWh
|
$2,140 | $11,250 | ||
TOTAL IMPLEMENTED | $15,220 | $1,540 |
$1,830
37,705
kWh
|
$2,140 | $11,250 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Personnel Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs