| Assessment Year | 2002 |
|---|---|
| Principal Product | Lumber |
| NAICS |
n/a
|
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $5 M to 10M |
| # of Employees | 80 |
| Plant Area |
n/a
|
| Annual Production | 23,500
thousand feet
|
| Production Hrs. Annual | 2,416
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $181,681 | 3,059,000 |
kWh
|
$0.059 |
| Electricity Demand | $51,147 | 14,379 |
kW-mo/yr
|
$3.56 |
| Electricity Fees | $4,515 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $43,950 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,460 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $28,700 | $76,400 | - | - | - | $28,700 | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,600 | $1,000 |
$5,600
121,800
kWh
|
- | - | - | |
| 03 | 2.3212: Optimize plant power factor | $5,000 | - | - |
$5,000
-
kW-mo/yr
|
- | - | |
| 04 | 2.8121: Apply for tax-free status for energy purchases | $2,800 | $5,600 | - | - | $2,800 | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $830 | $400 |
$830
18,000
kWh
|
- | - | - | |
| 06 | 2.6212: Turn off equipment during breaks, reduce operating time | $470 | - |
$470
10,300
kWh
|
- | - | - | |
| 07 | 2.4314: Use synthetic lubricant | $320 | - |
$250
5,450
kWh
|
$70
-
kW-mo/yr
|
- | - | |
| 08 | 2.7134: Use photocell controls | $230 | $40 |
$230
5,000
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $43,950 | $83,440 |
$7,380
160,550
kWh
|
$5,070
-
kW-mo/yr
|
$2,800 | $28,700 | ||
| TOTAL IMPLEMENTED | $14,460 | $7,040 |
$6,660
144,800
kWh
|
$5,000
-
kW-mo/yr
|
$2,800 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs