ITAC Assessment: AM0413
ITAC logo
ITAC Assessment: AM0413
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2002
Principal Product Lumber
NAICS
n/a
SIC 2421: Sawmills and Planing Mills, General
Sales Range $5
M
to 10
M
# of Employees 80
Plant Area
n/a
Annual Production 23,500
thousand feet
Production Hrs. Annual 2,416
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $181,681 3,059,000
kWh
Electricity Demand $51,147 14,379
kW-mo/yr
Electricity Fees $4,515 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $43,950 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $14,460

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings Ancillary Material Cost Savings
01 2.8114: Change rate schedules or other changes in utility service $28,700 $76,400 - - - $28,700
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,600 $1,000 $5,600
121,800
kWh
- - -
03 2.3212: Optimize plant power factor $5,000 - - $5,000
-
kW-mo/yr
- -
04 2.8121: Apply for tax-free status for energy purchases $2,800 $5,600 - - $2,800 -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $830 $400 $830
18,000
kWh
- - -
06 2.6212: Turn off equipment during breaks, reduce operating time $470 - $470
10,300
kWh
- - -
07 2.4314: Use synthetic lubricant $320 - $250
5,450
kWh
$70
-
kW-mo/yr
- -
08 2.7134: Use photocell controls $230 $40 $230
5,000
kWh
- - -
TOTAL RECOMMENDED $43,950 $83,440 $7,380
160,550
kWh
$5,070
-
kW-mo/yr
$2,800 $28,700
TOTAL IMPLEMENTED $14,460 $7,040 $6,660
144,800
kWh
$5,000
-
kW-mo/yr
$2,800 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs