| Assessment Year | 2002 |
|---|---|
| Principal Product | Polyethylene containers |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 50 |
| Plant Area |
84,000
ft2
|
| Annual Production | 12,500,000
pieces
|
| Production Hrs. Annual | 6,024
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $139,410 | 3,474,400 |
kWh
|
$0.040 |
| Electricity Demand | $63,414 | 7,780 |
kW-mo/yr
|
$8.15 |
| Electricity Fees | $3,322 | - |
|
- |
| Natural Gas | $26,140 | 4,120 |
MMBtu
|
$6.34 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $9,465 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,465 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $3,400 | $1,600 | - | - |
$3,400
-
MMBtu
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,975 | $2,250 |
$1,230
29,900
kWh
|
$745
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,460 | $200 |
$1,460
36,100
kWh
|
- | - | - | - | |
| 04 | 3.7131: Use a rag recycle service | $830 | - | - | - | - | - | $830 | |
| 05 | 3.7132: Reuse rags until completely soiled | $830 | - | - | - | - | - | $830 | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $520 | $320 |
$80
1,960
kWh
|
$35
-
kW-mo/yr
|
- | $405 | - | |
| 07 | 2.4239: Eliminate or reduce compressed air usage | $450 | $1,035 |
$450
10,930
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $9,465 | $5,405 |
$3,220
78,890
kWh
|
$780
-
kW-mo/yr
|
$3,400
-
MMBtu
|
$405 | $1,660 | ||
| TOTAL IMPLEMENTED | $9,465 | $5,405 |
$3,220
78,890
kWh
|
$780
-
kW-mo/yr
|
$3,400
-
MMBtu
|
$405 | $1,660 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs