| Assessment Year | 2001 |
|---|---|
| Principal Product | Springs |
| NAICS |
n/a
|
| SIC | 3493: Steel Springs, Except Wire |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
80,000
ft2
|
| Annual Production | 19,200
pieces
|
| Production Hrs. Annual | 3,336
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $81,461 | 1,245,600 |
kWh
|
$0.065 |
| Electricity Demand | $15,785 | 5,212 |
kW-mo/yr
|
$3.03 |
| Natural Gas | $117,138 | 19,312 |
MMBtu
|
$6.07 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $19,785 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,275 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $9,370 | $14,460 | - |
$9,370
-
kW-mo/yr
|
- | - | |
| 02 | 2.7145: Install skylights | $5,430 | $11,800 |
$5,430
77,600
kWh
|
- | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $875 | $580 |
$205
2,940
kWh
|
$20
-
kW-mo/yr
|
- | $650 | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,180 | $1,140 |
$920
13,190
kWh
|
$260
-
kW-mo/yr
|
- | - | |
| 05 | 2.2437: Recover waste heat from equipment | $1,080 | $100 |
$1,080
15,390
kWh
|
- | - | - | |
| 06 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $710 | $703 | - | - |
$710
-
MMBtu
|
- | |
| 07 | 2.7124: Make a practice of turning off lights when not needed | $870 | $445 |
$870
12,430
kWh
|
- | - | - | |
| 08 | 2.7123: Keep lamps and reflectors clean | $270 | $750 |
$210
2,960
kWh
|
$60
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $19,785 | $29,978 |
$8,715
124,510
kWh
|
$9,710
-
kW-mo/yr
|
$710
-
MMBtu
|
$650 | ||
| TOTAL IMPLEMENTED | $4,275 | $3,015 |
$3,285
46,910
kWh
|
$340
-
kW-mo/yr
|
- | $650 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs