| Assessment Year | 2020 |
|---|---|
| Principal Product | Chemical Compounds |
| NAICS | 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing |
| SIC | 2899: Chemicals and Chemical Preparations, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 46 |
| Plant Area |
152,460
ft2
|
| Annual Production | 8
ton
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $81,277 | 1,145,005 |
kWh
|
$0.071 |
| Electricity Demand | $24,434 | 2,284 |
kW-mo/yr
|
$10.70 |
| Electricity Fees | $18,510 | - |
|
- |
| TOTAL YEARLY COSTS | $124,221 | |||
| RECOMMENDED SAVINGS* | $63,652 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $45,967 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $40,475 | $333,760 |
$40,475
570,064
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $14,436 | $15,494 |
$11,934
168,092
kWh
|
$2,502
-
kW-mo/yr
|
|
| 03 | 2.4112: Install soft-start to eliminate nuisance trips | $5,492 | $4,295 |
$5,492
77,345
kWh
|
- | |
| 04 | 2.7135: Install occupancy sensors | $2,226 | $10,638 |
$2,226
31,346
kWh
|
- | |
| 05 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,023 | $60 |
$1,023
14,414
kWh
|
- | |
| TOTAL RECOMMENDED | $63,652 | $364,247 |
$61,150
861,261
kWh
|
$2,502
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $45,967 | $338,055 |
$45,967
647,409
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs