Assessment Year | 2001 |
---|---|
Principal Product | Treated lumber & plywood |
NAICS |
n/a
|
SIC | 2491: Wood Preserving |
Sales Range | $10 M to 50M |
# of Employees | 37 |
Plant Area |
n/a
|
Annual Production | 61,000
thousand feet
|
Production Hrs. Annual | 2,873
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $74,866 | 960,733 |
kWh
|
$0.078 |
Natural Gas | $104,199 | 17,554 |
MMBtu
|
$5.94 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,600 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,680 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $4,590 | $5,320 | - |
$4,590
-
kW-mo/yr
|
- | - | |
02 | 2.3212: Optimize plant power factor | $2,180 | $4,750 | - |
$2,180
-
kW-mo/yr
|
- | - | |
03 | 2.2511: Insulate bare equipment | $2,350 | $330 | - | - |
$2,350
-
MMBtu
|
- | |
04 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $690 | - | - | - | - |
$690
-
lb
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $350 | $245 |
$260
3,700
kWh
|
$90
-
kW-mo/yr
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $230 | $100 |
$230
3,200
kWh
|
- | - | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $110 | $20 |
$80
1,150
kWh
|
$30
-
kW-mo/yr
|
- | - | |
08 | 2.7134: Use photocell controls | $100 | - |
$65
1,100
kWh
|
$35
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $10,600 | $10,765 |
$635
9,150
kWh
|
$6,925
-
kW-mo/yr
|
$2,350
-
MMBtu
|
$690
-
lb
|
||
TOTAL IMPLEMENTED | $2,680 | $430 |
$295
4,300
kWh
|
$35
-
kW-mo/yr
|
$2,350
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs