Assessment Year 2001
Principal Product Steel drums
NAICS
n/a
SIC 3412: Metal Shipping Barrels, Drums, Kegs, and Pails
Sales Range $10
M
to 50
M
# of Employees 130
Plant Area 109,000
ft2
Annual Production 1,800,000
pieces
Production Hrs. Annual 2,875
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $349,083 5,047,215
kWh
Electricity Demand $111,637 17,746
kW-mo/yr
Natural Gas $181,713 52,642
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $190,240 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $85,180

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings Primary Product Savings
01 2.4322: Use or replace with energy efficient substitutes $97,950 $233,444 n/a - - $32,450
-
MMBtu
- $65,500 - -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $51,000 $2,500 $51,000
1,040,000
kWh
- - - - - -
03 3.2176: Increase use of automation $24,140 $57,000 $(-270.0)
(-5,500)
kWh
$(-340.0)
-
kW-mo/yr
- - - - $24,750
04 2.3212: Optimize plant power factor $7,000 $18,250 - $7,000
-
kW-mo/yr
- - - - -
05 3.1162: Use less wasteful packaging $5,000 $4,442 - - - $5,000
-
lb
- - -
06 4.821: Pay bills on time to avoid late fees $5,040 - - - - - - $5,040 -
07 2.7124: Make a practice of turning off lights when not needed $110 - $60
1,300
kWh
$50
-
kW-mo/yr
- - - - -
TOTAL RECOMMENDED $190,240 $315,636 $50,790
1,035,800
kWh
$6,710
-
kW-mo/yr
$32,450
-
MMBtu
$5,000
-
lb
$65,500 $5,040 $24,750
TOTAL IMPLEMENTED $85,180 $63,942 $50,730
1,034,500
kWh
$(-340.0)
-
kW-mo/yr
- $5,000
-
lb
- $5,040 $24,750
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs