Assessment Year | 2001 |
---|---|
Principal Product | Steel drums |
NAICS |
n/a
|
SIC | 3412: Metal Shipping Barrels, Drums, Kegs, and Pails |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
109,000
ft2
|
Annual Production | 1,800,000
pieces
|
Production Hrs. Annual | 2,875
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $349,083 | 5,047,215 |
kWh
|
$0.069 |
Electricity Demand | $111,637 | 17,746 |
kW-mo/yr
|
$6.29 |
Natural Gas | $181,713 | 52,642 |
MMBtu
|
$3.45 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $190,240 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $85,180 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $97,950 | $233,444 | n/a | - | - |
$32,450
-
MMBtu
|
- | $65,500 | - | - |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $51,000 | $2,500 |
$51,000
1,040,000
kWh
|
- | - | - | - | - | - | |
03 | 3.2176: Increase use of automation | $24,140 | $57,000 |
$(-270.0)
(-5,500)
kWh
|
$(-340.0)
-
kW-mo/yr
|
- | - | - | - | $24,750 | |
04 | 2.3212: Optimize plant power factor | $7,000 | $18,250 | - |
$7,000
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 3.1162: Use less wasteful packaging | $5,000 | $4,442 | - | - | - |
$5,000
-
lb
|
- | - | - | |
06 | 4.821: Pay bills on time to avoid late fees | $5,040 | - | - | - | - | - | - | $5,040 | - | |
07 | 2.7124: Make a practice of turning off lights when not needed | $110 | - |
$60
1,300
kWh
|
$50
-
kW-mo/yr
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $190,240 | $315,636 |
$50,790
1,035,800
kWh
|
$6,710
-
kW-mo/yr
|
$32,450
-
MMBtu
|
$5,000
-
lb
|
$65,500 | $5,040 | $24,750 | ||
TOTAL IMPLEMENTED | $85,180 | $63,942 |
$50,730
1,034,500
kWh
|
$(-340.0)
-
kW-mo/yr
|
- |
$5,000
-
lb
|
- | $5,040 | $24,750 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs