| Assessment Year | 2001 |
|---|---|
| Principal Product | Car wash equipment |
| NAICS |
n/a
|
| SIC | 3559: Special Industry Machinery, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 128 |
| Plant Area |
75,000
ft2
|
| Annual Production | 370
pieces
|
| Production Hrs. Annual | 2,536
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $59,984 | 1,007,034 |
kWh
|
$0.060 |
| Electricity Demand | $12,171 | 4,156 |
kW-mo/yr
|
$2.93 |
| Electricity Fees | $853 | - |
|
- |
| Natural Gas | $1,342 | 214 |
MMBtu
|
$6.27 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $23,738 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $21,762 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 4.111: Add equipment/ operators to reduce production bottleneck | $13,300 | $45,140 | - | - | $13,300 | - | |
| 02 | 2.3212: Optimize plant power factor | $3,480 | $5,820 | - |
$3,480
-
kW-mo/yr
|
- | - | |
| 03 | 2.7141: Lower light fixtures in high ceiling areas | $1,830 | $1,420 |
$1,310
20,809
kWh
|
$520
-
kW-mo/yr
|
- | - | |
| 04 | 2.3212: Optimize plant power factor | $1,710 | $3,300 | - |
$1,710
-
kW-mo/yr
|
- | - | |
| 05 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,450 | - |
$1,450
22,567
kWh
|
- | - | - | |
| 06 | 4.821: Pay bills on time to avoid late fees | $852 | - | - | - | - | $852 | |
| 07 | 2.7124: Make a practice of turning off lights when not needed | $620 | - |
$410
6,448
kWh
|
$210
-
kW-mo/yr
|
- | - | |
| 08 | 2.6212: Turn off equipment during breaks, reduce operating time | $190 | - |
$190
3,224
kWh
|
- | - | - | |
| 09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $160 | $110 |
$160
2,638
kWh
|
- | - | - | |
| 10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $146 | $70 |
$30
586
kWh
|
$6
-
kW-mo/yr
|
$110 | - | |
| TOTAL RECOMMENDED | $23,738 | $55,860 |
$3,550
56,272
kWh
|
$5,926
-
kW-mo/yr
|
$13,410 | $852 | ||
| TOTAL IMPLEMENTED | $21,762 | $54,370 |
$2,210
34,877
kWh
|
$5,400
-
kW-mo/yr
|
$13,300 | $852 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs