Assessment Year | 2001 |
---|---|
Principal Product | Metal drums, plastic drum inserts |
NAICS |
n/a
|
SIC | 3412: Metal Shipping Barrels, Drums, Kegs, and Pails |
Sales Range | $10 M to 50M |
# of Employees | 76 |
Plant Area |
180,000
ft2
|
Annual Production | 2,590,000
pieces
|
Production Hrs. Annual | 3,344
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $189,423 | 3,814,771 |
kWh
|
$0.050 |
Electricity Demand | $67,884 | 13,449 |
kW-mo/yr
|
$5.05 |
Electricity Fees | $3,649 | - |
|
- |
Natural Gas | $87,535 | 23,828 |
MMBtu
|
$3.67 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $23,631 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $12,670 | $18,600 | - |
$12,670
-
kW-mo/yr
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,650 | $500 |
$5,650
122,802
kWh
|
- | - | - | - | |
03 | 3.5313: Increase amount of waste recovered for resale | $1,615 | $5,500 | - | - | - |
$1,615
-
lb
|
- | |
04 | 2.8114: Change rate schedules or other changes in utility service | $1,420 | - | - | - | $1,420 | - | - | |
05 | 2.8123: Pay utility bills on time | $1,258 | - | - | - | $1,258 | - | - | |
06 | 2.7124: Make a practice of turning off lights when not needed | $520 | - |
$520
11,137
kWh
|
- | - | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $220 | $215 |
$90
20,809
kWh
|
$20
-
kW-mo/yr
|
- | - | $110 | |
08 | 2.7134: Use photocell controls | $178 | - |
$113
2,638
kWh
|
$65
-
kW-mo/yr
|
- | - | - | |
09 | 2.6212: Turn off equipment during breaks, reduce operating time | $100 | - |
$100
2,052
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $23,631 | $24,815 |
$6,473
159,438
kWh
|
$12,755
-
kW-mo/yr
|
$2,678 |
$1,615
-
lb
|
$110 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs