Assessment Year 2001
Principal Product Metal drums, plastic drum inserts
NAICS
n/a
SIC 3412: Metal Shipping Barrels, Drums, Kegs, and Pails
Sales Range $10
M
to 50
M
# of Employees 76
Plant Area 180,000
ft2
Annual Production 2,590,000
pieces
Production Hrs. Annual 3,344
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $189,423 3,814,771
kWh
Electricity Demand $67,884 13,449
kW-mo/yr
Electricity Fees $3,649 -
Natural Gas $87,535 23,828
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $23,631 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Solid Waste (non-haz) Savings Personnel Changes Savings
01 2.3212: Optimize plant power factor $12,670 $18,600 - $12,670
-
kW-mo/yr
- - -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,650 $500 $5,650
122,802
kWh
- - - -
03 3.5313: Increase amount of waste recovered for resale $1,615 $5,500 - - - $1,615
-
lb
-
04 2.8114: Change rate schedules or other changes in utility service $1,420 - - - $1,420 - -
05 2.8123: Pay utility bills on time $1,258 - - - $1,258 - -
06 2.7124: Make a practice of turning off lights when not needed $520 - $520
11,137
kWh
- - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $220 $215 $90
20,809
kWh
$20
-
kW-mo/yr
- - $110
08 2.7134: Use photocell controls $178 - $113
2,638
kWh
$65
-
kW-mo/yr
- - -
09 2.6212: Turn off equipment during breaks, reduce operating time $100 - $100
2,052
kWh
- - - -
TOTAL RECOMMENDED $23,631 $24,815 $6,473
159,438
kWh
$12,755
-
kW-mo/yr
$2,678 $1,615
-
lb
$110
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Solid Waste (non-haz) Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs