Assessment Year | 2001 |
---|---|
Principal Product | Softwood plywood |
NAICS |
n/a
|
SIC | 2436: Softwood Veneer and Plywood |
Sales Range | $50 M to 100M |
# of Employees | 350 |
Plant Area |
24,000
ft2
|
Annual Production | 180,000
thousand feet
|
Production Hrs. Annual | 8,640
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,237,338 | 36,672,000 |
kWh
|
$0.034 |
Electricity Demand | $488,585 | 74,028 |
kW-mo/yr
|
$6.60 |
Natural Gas | $98,999 | 27,304 |
MMBtu
|
$3.63 |
Wood | $484,000 | 1,411 |
MMBtu
|
$343.02 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $423,130 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Wood Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 4.114: Add/modify equipment to improve drying process | $303,000 | - | - | - |
$(-28,000.0)
-
MMBtu
|
- | - | $331,000 | |
02 | 2.2437: Recover waste heat from equipment | $62,000 | $5,000 | - | - |
$39,500
-
MMBtu
|
- | $22,500 | - | |
03 | 2.8114: Change rate schedules or other changes in utility service | $36,500 | - | - | $36,500 | - | - | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,500 | $250 |
$8,500
197,600
kWh
|
- | - | - | - | - | |
05 | 2.2514: Cover open tanks | $4,700 | $6,335 | - | - |
$4,700
-
MMBtu
|
- | - | - | |
06 | 2.7124: Make a practice of turning off lights when not needed | $4,500 | $1,440 |
$4,500
105,300
kWh
|
- | - | - | - | - | |
07 | 3.7198: Reduce / eliminate use of disposable product | $2,820 | $699 | - | - | - |
$2,820
-
lb
|
- | - | |
08 | 2.2135: Repair and eliminate steam leaks | $650 | $250 | - | - |
$650
-
MMBtu
|
- | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $460 | $340 |
$140
3,300
kWh
|
- | - | - | $320 | - | |
TOTAL RECOMMENDED | $423,130 | $14,314 |
$13,140
306,200
kWh
|
$36,500 |
$16,850
-
MMBtu
|
$2,820
-
lb
|
$22,820 | $331,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Wood Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs