Assessment Year | 2001 |
---|---|
Principal Product | Machined thermoplastic parts |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
65,000
ft2
|
Annual Production | 267,400
lb
|
Production Hrs. Annual | 4,448
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $68,007 | 1,058,617 |
kWh
|
$0.064 |
Electricity Demand | $14,679 | 4,865 |
kW-mo/yr
|
$3.02 |
Electricity Fees | $(-23.0) | - |
|
- |
Natural Gas | $33,690 | 4,126 |
MMBtu
|
$8.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $27,020 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,450 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $8,525 | $12,000 | - |
$8,525
-
kW-mo/yr
|
- | - | |
02 | 2.7141: Lower light fixtures in high ceiling areas | $6,630 | $8,810 |
$5,020
83,529
kWh
|
$1,610
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,900 | $250 |
$3,900
64,771
kWh
|
- | - | - | |
04 | 2.7124: Make a practice of turning off lights when not needed | $2,980 | $20 |
$2,240
37,222
kWh
|
$740
-
kW-mo/yr
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,395 | $20 |
$1,095
18,171
kWh
|
$300
-
kW-mo/yr
|
- | - | |
06 | 2.8121: Apply for tax-free status for energy purchases | $1,330 | $800 | - | - | - | $1,330 | |
07 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $1,200 | $7,500 | - | - |
$1,200
-
lb
|
- | |
08 | 2.8123: Pay utility bills on time | $960 | - | - | - | - | $960 | |
09 | 2.8114: Change rate schedules or other changes in utility service | $100 | - | - | - | - | $100 | |
TOTAL RECOMMENDED | $27,020 | $29,400 |
$12,255
203,693
kWh
|
$11,175
-
kW-mo/yr
|
$1,200
-
lb
|
$2,390 | ||
TOTAL IMPLEMENTED | $20,450 | $21,080 |
$10,015
166,471
kWh
|
$10,435
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs