Assessment Year | 2000 |
---|---|
Principal Product | Clay bricks |
NAICS |
n/a
|
SIC | 3251: Brick and Structural Clay Tile |
Sales Range | $5 M to 10M |
# of Employees | 55 |
Plant Area |
104,850
ft2
|
Annual Production | 33,000,000
pieces
|
Production Hrs. Annual | 8,670
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $87,761 | 2,530,774 |
kWh
|
$0.035 |
Electricity Demand | $37,138 | 4,846 |
kW-mo/yr
|
$7.66 |
Natural Gas | $380,679 | 146,532 |
MMBtu
|
$2.60 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,955 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,150 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $4,070 | $2,740 | - | - |
$4,070
-
MMBtu
|
- | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,090 | $8 |
$360
14,068
kWh
|
$730
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $950 | $850 |
$200
7,913
kWh
|
$440
-
kW-mo/yr
|
- | - | - | $310 | |
04 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $930 | $200 | - | - | - | - |
$930
-
lb
|
- | |
05 | 3.8132: Use less toxic and volatile solvent substitutes | $875 | $1,030 | - | - | - |
$875
-
gal
|
- | - | |
06 | 2.7124: Make a practice of turning off lights when not needed | $660 | - |
$230
8,792
kWh
|
$430
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $260 | $100 |
$260
9,965
kWh
|
- | - | - | - | - | |
08 | 2.7124: Make a practice of turning off lights when not needed | $120 | - |
$180
6,448
kWh
|
- | - | - | - | $(-60.0) | |
TOTAL RECOMMENDED | $8,955 | $4,928 |
$1,230
47,186
kWh
|
$1,600
-
kW-mo/yr
|
$4,070
-
MMBtu
|
$875
-
gal
|
$930
-
lb
|
$250 | ||
TOTAL IMPLEMENTED | $7,150 | $3,698 |
$1,230
47,186
kWh
|
$1,600
-
kW-mo/yr
|
$4,070
-
MMBtu
|
- | - | $250 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs