ITAC Assessment: AM0364
ITAC logo
ITAC Assessment: AM0364
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2000
Principal Product screw conveyors
NAICS
n/a
SIC 3535: Conveyors and Conveying Equipment
Sales Range $10
M
to 50
M
# of Employees 140
Plant Area 70,000
ft2
Annual Production 2,280,000
lb
Production Hrs. Annual 3,816
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $47,402 1,087,046
kWh
Electricity Demand $34,745 4,437
kW-mo/yr
Natural Gas $12,505 3,064
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $26,148 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $25,933

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Other Liquid (haz) Savings
01 3.2123: Convert to high volume low pressure (hvlp) paint guns $21,110 - - - $21,110
-
gal
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,970 $1,500 $2,970
118,992
kWh
- -
03 2.4133: Use most efficient type of electric motors $1,292 $6,900 $719
28,722
kWh
$573
-
kW-mo/yr
-
04 2.7134: Use photocell controls $420 $170 $180
6,448
kWh
$240
-
kW-mo/yr
-
05 2.7121: Utilize daylight whenever possible in lieu of artificial light $215 - $215
4,396
kWh
- -
06 2.4314: Use synthetic lubricant $141 - $130
4,103
kWh
$11
-
kW-mo/yr
-
TOTAL RECOMMENDED $26,148 $8,570 $4,214
162,661
kWh
$824
-
kW-mo/yr
$21,110
-
gal
TOTAL IMPLEMENTED $25,933 $8,570 $3,999
158,265
kWh
$824
-
kW-mo/yr
$21,110
-
gal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Other Liquid (haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs