Assessment Year | 2000 |
---|---|
Principal Product | screw conveyors |
NAICS |
n/a
|
SIC | 3535: Conveyors and Conveying Equipment |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
70,000
ft2
|
Annual Production | 2,280,000
lb
|
Production Hrs. Annual | 3,816
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $47,402 | 1,087,046 |
kWh
|
$0.044 |
Electricity Demand | $34,745 | 4,437 |
kW-mo/yr
|
$7.83 |
Natural Gas | $12,505 | 3,064 |
MMBtu
|
$4.08 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,148 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $25,933 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings |
---|---|---|---|---|---|---|---|
01 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $21,110 | - | - | - |
$21,110
-
gal
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,970 | $1,500 |
$2,970
118,992
kWh
|
- | - | |
03 | 2.4133: Use most efficient type of electric motors | $1,292 | $6,900 |
$719
28,722
kWh
|
$573
-
kW-mo/yr
|
- | |
04 | 2.7134: Use photocell controls | $420 | $170 |
$180
6,448
kWh
|
$240
-
kW-mo/yr
|
- | |
05 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $215 | - |
$215
4,396
kWh
|
- | - | |
06 | 2.4314: Use synthetic lubricant | $141 | - |
$130
4,103
kWh
|
$11
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $26,148 | $8,570 |
$4,214
162,661
kWh
|
$824
-
kW-mo/yr
|
$21,110
-
gal
|
||
TOTAL IMPLEMENTED | $25,933 | $8,570 |
$3,999
158,265
kWh
|
$824
-
kW-mo/yr
|
$21,110
-
gal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs