ITAC Assessment: AM0360
ITAC logo
ITAC Assessment: AM0360
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1999
Principal Product process vessels, fabricated pipe
NAICS
n/a
SIC 3443: Fabricated Plate Work (Boiler Shops)
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 240,000
ft2
Annual Production 3,000,000
lb
Production Hrs. Annual 2,702
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $86,025 1,687,866
kWh
Electricity Demand $62,836 8,191
kW-mo/yr
Natural Gas $51,649 12,569
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $20,200 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $20,200

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7231: Use radiant heater for spot heating $13,800 $12,800 - - $13,800
-
MMBtu
02 2.7124: Make a practice of turning off lights when not needed $2,360 - $1,180
28,722
kWh
$1,180
-
kW-mo/yr
-
03 2.7124: Make a practice of turning off lights when not needed $1,140 - $1,140
27,843
kWh
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,100 $500 $1,100
26,964
kWh
- -
05 2.7121: Utilize daylight whenever possible in lieu of artificial light $1,090 - $1,090
26,671
kWh
- -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $420 $200 $420
10,258
kWh
- -
07 2.7135: Install occupancy sensors $190 $110 $190
4,689
kWh
- -
08 2.6212: Turn off equipment during breaks, reduce operating time $100 - $100
586
kWh
- -
TOTAL RECOMMENDED $20,200 $13,610 $5,220
125,733
kWh
$1,180
-
kW-mo/yr
$13,800
-
MMBtu
TOTAL IMPLEMENTED $20,200 $13,610 $5,220
125,733
kWh
$1,180
-
kW-mo/yr
$13,800
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs