Assessment Year | 1999 |
---|---|
Principal Product | flanges, pressure vessel nozzles |
NAICS |
n/a
|
SIC | 3494: Valves and Pipe Fittings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
37,000
ft2
|
Annual Production | 75,000
pieces
|
Production Hrs. Annual | 4,536
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $114,038 | 2,383,353 |
kWh
|
$0.048 |
Electricity Demand | $84,749 | 16,031 |
kW-mo/yr
|
$5.29 |
Electricity Fees | $7,232 | - |
|
- |
Natural Gas | $462,745 | 134,556 |
MMBtu
|
$3.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,601 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $25,337 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $10,000 | $19,540 | - |
$10,000
-
kW-mo/yr
|
- | - | - | - | - | |
02 | 2.8121: Apply for tax-free status for energy purchases | $7,600 | $3,800 | - | - | $7,600 | - | - | - | - | |
03 | 3.4155: Meter waste water | $5,200 | $8,500 | - | - | - | - |
$5,200
-
Tgal
|
- | - | |
04 | 2.7124: Make a practice of turning off lights when not needed | $3,545 | - |
$3,120
42,790
kWh
|
$425
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.2511: Insulate bare equipment | $1,130 | $670 | - | - | - |
$1,130
-
MMBtu
|
- | - | - | |
06 | 4.821: Pay bills on time to avoid late fees | $1,122 | - | - | - | - | - | - | - | $1,122 | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,040 | $250 |
$1,040
14,361
kWh
|
- | - | - | - | - | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $915 | $19 |
$825
11,430
kWh
|
$90
-
kW-mo/yr
|
- | - | - | - | - | |
09 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $900 | - |
$900
12,309
kWh
|
- | - | - | - | - | - | |
10 | 3.7198: Reduce / eliminate use of disposable product | $149 | $150 | - | - | - | - | - |
$149
-
lb
|
- | |
TOTAL RECOMMENDED | $31,601 | $32,929 |
$5,885
80,890
kWh
|
$10,515
-
kW-mo/yr
|
$7,600 |
$1,130
-
MMBtu
|
$5,200
-
Tgal
|
$149
-
lb
|
$1,122 | ||
TOTAL IMPLEMENTED | $25,337 | $24,260 |
$5,060
69,460
kWh
|
$10,425
-
kW-mo/yr
|
$7,600 |
$1,130
-
MMBtu
|
- | - | $1,122 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs