ITAC Assessment: AM0341
ITAC logo
ITAC Assessment: AM0341
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1999
Principal Product Gypsum wallboard
NAICS
n/a
SIC 3275: Gypsum Products
Sales Range $10
M
to 50
M
# of Employees 180
Plant Area 275,000
ft2
Annual Production 250,000
thousand feet
Production Hrs. Annual 0
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,399,546 50,674,678
kWh
Electricity Demand $419,225 100,667
kW-mo/yr
Natural Gas $2,371,040 956,694
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $43,905 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $42,135

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $15,300 $500 - - $15,300
-
MMBtu
02 2.1233: Analyze flue gas for proper air/fuel ratio $11,600 $500 - - $11,600
-
MMBtu
03 2.7142: Utilize higher efficiency lamps and/or ballasts $4,760 $18,630 $2,600
119,871
kWh
$2,160
-
kW-mo/yr
-
04 2.2135: Repair and eliminate steam leaks $6,140 $780 - - $6,140
-
MMBtu
05 2.4314: Use synthetic lubricant $3,380 - $1,820
83,822
kWh
$1,560
-
kW-mo/yr
-
06 2.7121: Utilize daylight whenever possible in lieu of artificial light $720 - $720
33,118
kWh
- -
07 2.7121: Utilize daylight whenever possible in lieu of artificial light $650 - $650
30,188
kWh
- -
08 2.2511: Insulate bare equipment $540 $905 - - $540
-
MMBtu
09 2.4314: Use synthetic lubricant $415 - $220
9,965
kWh
$195
-
kW-mo/yr
-
10 2.7111: Reduce illumination to minimum necessary levels $250 - $250
11,723
kWh
- -
11 2.7121: Utilize daylight whenever possible in lieu of artificial light $150 - $150
7,034
kWh
- -
TOTAL RECOMMENDED $43,905 $21,315 $6,410
295,721
kWh
$3,915
-
kW-mo/yr
$33,580
-
MMBtu
TOTAL IMPLEMENTED $42,135 $21,315 $4,640
213,658
kWh
$3,915
-
kW-mo/yr
$33,580
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs