Assessment Year | 1999 |
---|---|
Principal Product | Coops for transportation of live poultry |
NAICS |
n/a
|
SIC | 3496: Miscellaneous Fabricated Wire Products |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
n/a
|
Annual Production | 10,345
pieces
|
Production Hrs. Annual | 2,517
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $52,686 | 992,966 |
kWh
|
$0.053 |
Electricity Demand | $40,288 | 4,970 |
kW-mo/yr
|
$8.11 |
Natural Gas | $48,097 | 12,853 |
MMBtu
|
$3.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $90,855 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $89,330 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.111: Add equipment/ operators to reduce production bottleneck | $84,980 | $80,500 | - | - | $(-41,330.0) | - | $126,310 | |
02 | 2.7124: Make a practice of turning off lights when not needed | $3,750 | - |
$3,750
75,029
kWh
|
- | - | - | - | |
03 | 2.8121: Apply for tax-free status for energy purchases | $640 | $800 | - | - | - | $640 | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $600 | $100 |
$600
12,016
kWh
|
- | - | - | - | |
05 | 2.7124: Make a practice of turning off lights when not needed | $460 | - |
$200
4,103
kWh
|
$260
-
kW-mo/yr
|
- | - | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $290 | $14 |
$130
2,638
kWh
|
$160
-
kW-mo/yr
|
- | - | - | |
07 | 2.6212: Turn off equipment during breaks, reduce operating time | $135 | - |
$135
1,758
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $90,855 | $81,414 |
$4,815
95,544
kWh
|
$420
-
kW-mo/yr
|
$(-41,330.0) | $640 | $126,310 | ||
TOTAL IMPLEMENTED | $89,330 | $80,600 |
$4,350
87,045
kWh
|
- | $(-41,330.0) | - | $126,310 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs