ITAC Assessment: AM0329
ITAC logo
ITAC Assessment: AM0329
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1998
Principal Product Polyester fiber for apparel insulation and furniture
NAICS
n/a
SIC 2293:
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 200,000
ft2
Annual Production 10,000,000
pieces
Production Hrs. Annual 7,008
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $119,859 3,348,183
kWh
Electricity Demand $65,232 7,962
kW-mo/yr
Natural Gas $146,382 39,029
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $7,103 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,413

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Administrative Changes Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,000 $500 $3,000
134,818
kWh
- - -
02 3.5212: Regrind, reuse, or sell scrap plastic parts $1,175 $300 - - $1,100
-
lb
$75
03 2.7124: Make a practice of turning off lights when not needed $750 $420 $750
32,532
kWh
- - -
04 2.4314: Use synthetic lubricant $515 - $265
11,723
kWh
$250
-
kW-mo/yr
- -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $445 - $230
9,672
kWh
$215
-
kW-mo/yr
- -
06 2.8121: Apply for tax-free status for energy purchases $393 $392 - - - $393
07 2.7142: Utilize higher efficiency lamps and/or ballasts $375 $190 $95
4,103
kWh
$280
-
kW-mo/yr
- -
08 2.4133: Use most efficient type of electric motors $360 $740 $180
8,206
kWh
$180
-
kW-mo/yr
- -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $90 $600 $50
2,345
kWh
$40
-
kW-mo/yr
- -
TOTAL RECOMMENDED $7,103 $3,142 $4,570
203,399
kWh
$965
-
kW-mo/yr
$1,100
-
lb
$468
TOTAL IMPLEMENTED $5,413 $2,842 $4,305
191,676
kWh
$715
-
kW-mo/yr
- $393
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs