Assessment Year | 1998 |
---|---|
Principal Product | Polyester fiber for apparel insulation and furniture |
NAICS |
n/a
|
SIC | 2293: |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
200,000
ft2
|
Annual Production | 10,000,000
pieces
|
Production Hrs. Annual | 7,008
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $119,859 | 3,348,183 |
kWh
|
$0.036 |
Electricity Demand | $65,232 | 7,962 |
kW-mo/yr
|
$8.19 |
Natural Gas | $146,382 | 39,029 |
MMBtu
|
$3.75 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,103 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,413 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,000 | $500 |
$3,000
134,818
kWh
|
- | - | - | |
02 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $1,175 | $300 | - | - |
$1,100
-
lb
|
$75 | |
03 | 2.7124: Make a practice of turning off lights when not needed | $750 | $420 |
$750
32,532
kWh
|
- | - | - | |
04 | 2.4314: Use synthetic lubricant | $515 | - |
$265
11,723
kWh
|
$250
-
kW-mo/yr
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $445 | - |
$230
9,672
kWh
|
$215
-
kW-mo/yr
|
- | - | |
06 | 2.8121: Apply for tax-free status for energy purchases | $393 | $392 | - | - | - | $393 | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $375 | $190 |
$95
4,103
kWh
|
$280
-
kW-mo/yr
|
- | - | |
08 | 2.4133: Use most efficient type of electric motors | $360 | $740 |
$180
8,206
kWh
|
$180
-
kW-mo/yr
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $90 | $600 |
$50
2,345
kWh
|
$40
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $7,103 | $3,142 |
$4,570
203,399
kWh
|
$965
-
kW-mo/yr
|
$1,100
-
lb
|
$468 | ||
TOTAL IMPLEMENTED | $5,413 | $2,842 |
$4,305
191,676
kWh
|
$715
-
kW-mo/yr
|
- | $393 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs