Assessment Year | 1998 |
---|---|
Principal Product | Corrugated boxes and sheeting |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
168,000
ft2
|
Annual Production | 750,000
thousand feet
|
Production Hrs. Annual | 3,944
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $205,973 | 5,422,919 |
kWh
|
$0.038 |
Electricity Demand | $79,642 | 12,702 |
kW-mo/yr
|
$6.27 |
Natural Gas | $129,005 | 36,847 |
MMBtu
|
$3.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $62,598 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $41,108 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.1192: Reduce scrap production | $38,400 | - | - | - | - |
$38,400
-
lb
|
- | |
02 | 2.8114: Change rate schedules or other changes in utility service | $15,390 | $1,600 | - | - | - | - | $15,390 | |
03 | 3.4155: Meter waste water | $2,300 | $6,200 | - | - |
$2,300
-
Tgal
|
- | - | |
04 | 3.4115: Recover and reuse cooling water | $2,200 | $3,000 | - | - |
$2,200
-
Tgal
|
- | - | |
05 | 2.7124: Make a practice of turning off lights when not needed | $1,600 | - |
$1,600
67,409
kWh
|
- | - | - | - | |
06 | 2.7124: Make a practice of turning off lights when not needed | $1,290 | $30 |
$1,290
52,755
kWh
|
- | - | - | - | |
07 | 4.821: Pay bills on time to avoid late fees | $763 | - | - | - | - | - | $763 | |
08 | 2.7124: Make a practice of turning off lights when not needed | $390 | - |
$390
16,120
kWh
|
- | - | - | - | |
09 | 4.652: Replace existing equipment with more suitable substitutes | $265 | $635 |
$65
2,638
kWh
|
$45
-
kW-mo/yr
|
- | - | $155 | |
TOTAL RECOMMENDED | $62,598 | $11,465 |
$3,345
138,922
kWh
|
$45
-
kW-mo/yr
|
$4,500
-
Tgal
|
$38,400
-
lb
|
$16,308 | ||
TOTAL IMPLEMENTED | $41,108 | $665 |
$1,745
71,513
kWh
|
$45
-
kW-mo/yr
|
- |
$38,400
-
lb
|
$918 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs