Assessment Year 1998
Principal Product Corrugated boxes and sheeting
NAICS
n/a
SIC 2653: Corrugated and Solid Fiber Boxes
Sales Range $10
M
to 50
M
# of Employees 130
Plant Area 168,000
ft2
Annual Production 750,000
thousand feet
Production Hrs. Annual 3,944
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $205,973 5,422,919
kWh
Electricity Demand $79,642 12,702
kW-mo/yr
Natural Gas $129,005 36,847
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $62,598 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $41,108

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Solid Waste (non-haz) Savings Administrative Changes Savings
01 3.1192: Reduce scrap production $38,400 - - - - $38,400
-
lb
-
02 2.8114: Change rate schedules or other changes in utility service $15,390 $1,600 - - - - $15,390
03 3.4155: Meter waste water $2,300 $6,200 - - $2,300
-
Tgal
- -
04 3.4115: Recover and reuse cooling water $2,200 $3,000 - - $2,200
-
Tgal
- -
05 2.7124: Make a practice of turning off lights when not needed $1,600 - $1,600
67,409
kWh
- - - -
06 2.7124: Make a practice of turning off lights when not needed $1,290 $30 $1,290
52,755
kWh
- - - -
07 4.821: Pay bills on time to avoid late fees $763 - - - - - $763
08 2.7124: Make a practice of turning off lights when not needed $390 - $390
16,120
kWh
- - - -
09 4.652: Replace existing equipment with more suitable substitutes $265 $635 $65
2,638
kWh
$45
-
kW-mo/yr
- - $155
TOTAL RECOMMENDED $62,598 $11,465 $3,345
138,922
kWh
$45
-
kW-mo/yr
$4,500
-
Tgal
$38,400
-
lb
$16,308
TOTAL IMPLEMENTED $41,108 $665 $1,745
71,513
kWh
$45
-
kW-mo/yr
- $38,400
-
lb
$918
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Solid Waste (non-haz) Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs