Assessment Year | 1998 |
---|---|
Principal Product | Asphalt roofing shingles |
NAICS |
n/a
|
SIC | 2952: Asphalt Felts and Coatings |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
141,750
ft2
|
Annual Production | 132,000,000
pieces
|
Production Hrs. Annual | 7,992
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $129,724 | 5,788,394 |
kWh
|
$0.022 |
Electricity Demand | $94,940 | 15,142 |
kW-mo/yr
|
$6.27 |
Natural Gas | $59,358 | 18,040 |
MMBtu
|
$3.29 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $87,427 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,757 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.5311: Recover and reuse waste material | $35,800 | $137,500 | - | - | - |
$(-1,800.0)
-
MMBtu
|
$37,600
-
lb
|
- | - | |
02 | 2.3212: Optimize plant power factor | $23,300 | $25,000 | - |
$23,300
-
kW-mo/yr
|
- | - | - | - | - | |
03 | 3.5311: Recover and reuse waste material | $12,000 | $410 | - | - | - | - | - | $12,000 | - | |
04 | 3.5311: Recover and reuse waste material | $10,900 | $9,000 | - | - | - | - | - | - | $10,900 | |
05 | 2.8123: Pay utility bills on time | $2,662 | - | - | - | $2,662 | - | - | - | - | |
06 | 2.7111: Reduce illumination to minimum necessary levels | $1,540 | - |
$580
24,326
kWh
|
$960
-
kW-mo/yr
|
- | - | - | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $555 | $320 |
$555
23,154
kWh
|
- | - | - | - | - | - | |
08 | 2.7124: Make a practice of turning off lights when not needed | $540 | - |
$540
22,567
kWh
|
- | - | - | - | - | - | |
09 | 2.7111: Reduce illumination to minimum necessary levels | $130 | $24 |
$70
3,224
kWh
|
$60
-
kW-mo/yr
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $87,427 | $172,254 |
$1,745
73,271
kWh
|
$24,320
-
kW-mo/yr
|
$2,662 |
$(-1,800.0)
-
MMBtu
|
$37,600
-
lb
|
$12,000 | $10,900 | ||
TOTAL IMPLEMENTED | $16,757 | $730 |
$1,135
47,480
kWh
|
$960
-
kW-mo/yr
|
$2,662 | - | - | $12,000 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs