| Assessment Year | 1998 |
|---|---|
| Principal Product | Industrial and marine lighting fixtures |
| NAICS |
n/a
|
| SIC | 3646: Commercial, Industrial, and Institutional Electric Lighting Fixtures |
| Sales Range | $10 M to 50M |
| # of Employees | 163 |
| Plant Area |
100,700
ft2
|
| Annual Production | 41,500
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $94,031 | 1,413,247 |
kWh
|
$0.067 |
| Electricity Demand | $27,305 | 9,258 |
kW-mo/yr
|
$2.95 |
| Electricity Fees | $2,129 | - |
|
- |
| Natural Gas | $20,580 | 5,245 |
MMBtu
|
$3.92 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $28,437 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,377 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $9,700 | $7,500 | - | - | - |
$2,900
-
lb
|
$6,800 | |
| 02 | 3.7198: Reduce / eliminate use of disposable product | $7,280 | $150 | - | - | - |
$7,280
-
lb
|
- | |
| 03 | 2.3212: Optimize plant power factor | $4,495 | $4,715 | - |
$4,495
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,200 | $1,000 |
$2,200
39,859
kWh
|
- | - | - | - | |
| 05 | 3.5316: Contract a wood pallet recycling company | $2,080 | - | - | - | - |
$2,080
-
lb
|
- | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,200 | $300 |
$1,200
22,860
kWh
|
- | - | - | - | |
| 07 | 2.8121: Apply for tax-free status for energy purchases | $1,022 | $840 | - | - | $1,022 | - | - | |
| 08 | 4.821: Pay bills on time to avoid late fees | $460 | - | - | - | $460 | - | - | |
| TOTAL RECOMMENDED | $28,437 | $14,505 |
$3,400
62,719
kWh
|
$4,495
-
kW-mo/yr
|
$1,482 |
$12,260
-
lb
|
$6,800 | ||
| TOTAL IMPLEMENTED | $9,377 | $6,855 |
$3,400
62,719
kWh
|
$4,495
-
kW-mo/yr
|
$1,482 | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs