| Assessment Year | 1997 |
|---|---|
| Principal Product | Processed beef and chicken, and other meat and poultry |
| NAICS |
n/a
|
| SIC | 2011: Meat Packing Plants |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
15,000
ft2
|
| Annual Production | 25,000,000
lb
|
| Production Hrs. Annual | 4,080
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $96,608 | 2,124,267 |
kWh
|
$0.045 |
| Electricity Demand | $14,803 | 5,375 |
kW-mo/yr
|
$2.75 |
| Electricity Fees | $3,692 | - |
|
- |
| Natural Gas | $3,730 | 693 |
MMBtu
|
$5.38 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $121,019 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $121,019 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.5311: Recover and reuse waste material | $114,000 | $3,000 | - | - | - |
$114,000
-
lb
|
- | |
| 02 | 2.3212: Optimize plant power factor | $2,930 | $3,040 | - |
$2,930
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.3212: Optimize plant power factor | $1,600 | $1,750 | - |
$1,600
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.3212: Optimize plant power factor | $1,000 | $1,085 | - |
$1,000
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $595 | $480 |
$70
2,638
kWh
|
$45
-
kW-mo/yr
|
- | - | $480 | |
| 06 | 2.7124: Make a practice of turning off lights when not needed | $505 | - |
$505
18,757
kWh
|
- | - | - | - | |
| 07 | 2.8121: Apply for tax-free status for energy purchases | $242 | $800 | - | - | $242 | - | - | |
| 08 | 2.7124: Make a practice of turning off lights when not needed | $147 | - |
$50
1,758
kWh
|
$97
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $121,019 | $10,155 |
$625
23,153
kWh
|
$5,672
-
kW-mo/yr
|
$242 |
$114,000
-
lb
|
$480 | ||
| TOTAL IMPLEMENTED | $121,019 | $10,155 |
$625
23,153
kWh
|
$5,672
-
kW-mo/yr
|
$242 |
$114,000
-
lb
|
$480 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs