Assessment Year | 1997 |
---|---|
Principal Product | Corrugated fiberboard sheets |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $50 M to 100M |
# of Employees | 150 |
Plant Area |
135,000
ft2
|
Annual Production | 1,000,000
thousand feet
|
Production Hrs. Annual | 4,554
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $83,111 | 2,280,188 |
kWh
|
$0.036 |
Electricity Demand | $41,993 | 5,115 |
kW-mo/yr
|
$8.21 |
Electricity Fees | $168 | - |
|
- |
Natural Gas | $213,482 | 60,500 |
MMBtu
|
$3.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,610 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,460 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.4115: Recover and reuse cooling water | $7,000 | $4,100 | - | - | - |
$7,000
-
Tgal
|
- | |
02 | 2.2136: Install / repair insulation on steam lines | $3,100 | $5,630 | - | - |
$3,100
-
MMBtu
|
- | - | |
03 | 2.7131: Add area lighting switches | $2,150 | $1,290 |
$950
36,342
kWh
|
$1,200
-
kW-mo/yr
|
- | - | - | |
04 | 3.4116: Meter recycled water (to reduce sewer charges) | $2,100 | $2,500 | - | - | - | - |
$2,100
-
Tgal
|
|
05 | 2.2135: Repair and eliminate steam leaks | $1,980 | $210 | - | - |
$1,980
-
MMBtu
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,860 | $780 |
$520
20,223
kWh
|
$1,340
-
kW-mo/yr
|
- | - | - | |
07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,060 | $500 | - | - |
$1,060
-
MMBtu
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $360 | $25 |
$160
6,155
kWh
|
$200
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $19,610 | $15,035 |
$1,630
62,720
kWh
|
$2,740
-
kW-mo/yr
|
$6,140
-
MMBtu
|
$7,000
-
Tgal
|
$2,100
-
Tgal
|
||
TOTAL IMPLEMENTED | $17,460 | $13,745 |
$680
26,378
kWh
|
$1,540
-
kW-mo/yr
|
$6,140
-
MMBtu
|
$7,000
-
Tgal
|
$2,100
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs