Assessment Year | 1997 |
---|---|
Principal Product | Molded rubber products |
NAICS |
n/a
|
SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 38 |
Plant Area |
26,000
ft2
|
Annual Production | 600,000
pieces
|
Production Hrs. Annual | 5,952
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $69,464 | 1,474,209 |
kWh
|
$0.047 |
Electricity Demand | $18,903 | 3,941 |
kW-mo/yr
|
$4.80 |
Natural Gas | $20,253 | 5,200 |
MMBtu
|
$3.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $12,587 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,007 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3134: Shift from daytime to nighttime operation | $2,220 | - |
$(-1,510.0)
(-32,825)
kWh
|
$5,600
-
kW-mo/yr
|
- | - | $(-1,870.0) | - | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $4,380 | $10,440 | - | - |
$4,380
-
MMBtu
|
- | - | - | |
03 | 2.2135: Repair and eliminate steam leaks | $1,580 | $430 | - | - |
$1,580
-
MMBtu
|
- | - | - | |
04 | 2.7145: Install skylights | $900 | $2,700 |
$900
19,637
kWh
|
- | - | - | - | - | |
05 | 2.2136: Install / repair insulation on steam lines | $1,200 | $150 | - | - |
$1,200
-
MMBtu
|
- | - | - | |
06 | 2.8121: Apply for tax-free status for energy purchases | $1,197 | $800 | - | - | - | - | - | $1,197 | |
07 | 2.1233: Analyze flue gas for proper air/fuel ratio | $430 | $420 | - | - |
$430
-
MMBtu
|
- | - | - | |
08 | 2.7124: Make a practice of turning off lights when not needed | $380 | - |
$260
5,569
kWh
|
$120
-
kW-mo/yr
|
- | - | - | - | |
09 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $300 | - | - | - | - |
$300
-
lb
|
- | - | |
TOTAL RECOMMENDED | $12,587 | $14,940 |
$(-350.0)
(-7,619)
kWh
|
$5,720
-
kW-mo/yr
|
$7,590
-
MMBtu
|
$300
-
lb
|
$(-1,870.0) | $1,197 | ||
TOTAL IMPLEMENTED | $7,007 | $1,800 |
$(-1,250.0)
(-27,256)
kWh
|
$5,720
-
kW-mo/yr
|
$3,210
-
MMBtu
|
- | $(-1,870.0) | $1,197 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs