Assessment Year | 1996 |
---|---|
Principal Product | Shrimp & Catfish |
NAICS |
n/a
|
SIC | 2092: Prepared Fresh or Frozen Fish and Seafoods |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
32,600
ft2
|
Annual Production | 4,300,000
lb
|
Production Hrs. Annual | 2,280
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $89,064 | 1,570,047 |
kWh
|
$0.057 |
Electricity Demand | $21,769 | 7,063 |
kW-mo/yr
|
$3.08 |
Electricity Fees | $3,519 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $114,418 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $99,948 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 3.1191: Change procedures / equipment / operating conditions | $95,600 | $1,500 | - | - | - |
$80,200
-
lb
|
$15,400 | |
02 | 2.3212: Optimize plant power factor | $14,320 | $14,320 | - |
$14,320
-
kW-mo/yr
|
- | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $150 | $180 |
$70
1,465
kWh
|
$80
-
kW-mo/yr
|
- | - | - | |
04 | 2.3132: Recharge batteries on during off-peak demand periods | $2,250 | $2,370 | - |
$2,250
-
kW-mo/yr
|
- | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $950 | $470 |
$550
11,430
kWh
|
$400
-
kW-mo/yr
|
- | - | - | |
06 | 2.8123: Pay utility bills on time | $903 | - | - | - | $903 | - | - | |
07 | 2.8112: Combine utility meters | $245 | - | - | - | $245 | - | - | |
TOTAL RECOMMENDED | $114,418 | $18,840 |
$620
12,895
kWh
|
$17,050
-
kW-mo/yr
|
$1,148 |
$80,200
-
lb
|
$15,400 | ||
TOTAL IMPLEMENTED | $99,948 | $4,340 |
$550
11,430
kWh
|
$2,650
-
kW-mo/yr
|
$1,148 |
$80,200
-
lb
|
$15,400 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs