Assessment Year 1996
Principal Product Business forms
NAICS
n/a
SIC 2761: Manifold Business Forms
Sales Range $10
M
to 50
M
# of Employees 113
Plant Area 65,000
ft2
Annual Production 20,370,000
lb
Production Hrs. Annual 6,416
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $90,616 3,042,790
kWh
Electricity Demand $60,574 7,080
kW-mo/yr
Electricity Fees $5,804 -
Natural Gas $1,777 319
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $5,991 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,611

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Solid Waste (non-haz) Savings Personnel Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $1,780 $530 $150
4,982
kWh
$60
-
kW-mo/yr
- - $1,570
02 2.4133: Use most efficient type of electric motors $950 $490 $560
18,464
kWh
$390
-
kW-mo/yr
- - -
03 2.4314: Use synthetic lubricant $790 - $460
15,240
kWh
$330
-
kW-mo/yr
- - -
04 2.8123: Pay utility bills on time $636 - - - $636 - -
05 2.4231: Reduce the pressure of compressed air to the minimum required $590 $20 $390
13,189
kWh
$200
-
kW-mo/yr
- - -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $560 $200 $560
18,757
kWh
- - - -
07 2.7124: Make a practice of turning off lights when not needed $425 - $280
9,086
kWh
$145
-
kW-mo/yr
- - -
08 3.7198: Reduce / eliminate use of disposable product $260 $110 - - - $260
-
lb
-
TOTAL RECOMMENDED $5,991 $1,350 $2,400
79,718
kWh
$1,125
-
kW-mo/yr
$636 $260
-
lb
$1,570
TOTAL IMPLEMENTED $4,611 $1,330 $1,550
51,289
kWh
$595
-
kW-mo/yr
$636 $260
-
lb
$1,570
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Solid Waste (non-haz) Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs