Assessment Year | 1996 |
---|---|
Principal Product | Soft drinks |
NAICS |
n/a
|
SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
Sales Range | $50 M to 100M |
# of Employees | 280 |
Plant Area |
315,000
ft2
|
Annual Production | 135,000,000
Tgal
|
Production Hrs. Annual | 5,620
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $379,203 | 10,779,602 |
kWh
|
$0.035 |
Electricity Demand | $196,618 | 23,245 |
kW-mo/yr
|
$8.46 |
Electricity Fees | $288 | - |
|
- |
Natural Gas | $197,600 | 46,900 |
MMBtu
|
$4.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,480 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,800 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7145: Install skylights | $4,180 | $10,200 |
$4,180
160,903
kWh
|
- | - | - | - | - | |
02 | 2.2135: Repair and eliminate steam leaks | $2,740 | $80 | - | - |
$2,740
-
MMBtu
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,700 | $1,620 |
$390
14,947
kWh
|
$250
-
kW-mo/yr
|
- | - | - | $2,060 | |
04 | 2.7124: Make a practice of turning off lights when not needed | $2,420 | $120 |
$760
29,308
kWh
|
$1,660
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4314: Use synthetic lubricant | $1,900 | - |
$930
35,756
kWh
|
$970
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.7145: Install skylights | $1,230 | $6,590 |
$1,230
47,186
kWh
|
- | - | - | - | - | |
07 | 2.4133: Use most efficient type of electric motors | $740 | $1,310 |
$350
13,482
kWh
|
$390
-
kW-mo/yr
|
- | - | - | - | |
08 | 3.8211: Convert to aqueous cleaning system | $570 | $1,050 | - | - | - |
$(-460.0)
-
gal
|
$1,030
-
gal
|
- | |
TOTAL RECOMMENDED | $16,480 | $20,970 |
$7,840
301,582
kWh
|
$3,270
-
kW-mo/yr
|
$2,740
-
MMBtu
|
$(-460.0)
-
gal
|
$1,030
-
gal
|
$2,060 | ||
TOTAL IMPLEMENTED | $7,800 | $1,510 |
$2,040
78,546
kWh
|
$3,020
-
kW-mo/yr
|
$2,740
-
MMBtu
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs