Assessment Year | 1996 |
---|---|
Principal Product | O-rings, lip seals, V-packing |
NAICS |
n/a
|
SIC | 3053: Gaskets, Packing, and Sealing Devices |
Sales Range | $5 M to 10M |
# of Employees | 85 |
Plant Area |
32,500
ft2
|
Annual Production | 1,500,000
pieces
|
Production Hrs. Annual | 4,675
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $96,917 | 1,806,272 |
kWh
|
$0.054 |
Electricity Demand | $17,551 | 5,282 |
kW-mo/yr
|
$3.32 |
Electricity Fees | $1,035 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,002 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,830 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,635 | $620 |
$1,035
41,325
kWh
|
$1,600
-
kW-mo/yr
|
- | - | - | - | - | |
02 | 2.8114: Change rate schedules or other changes in utility service | $1,317 | - | - |
$(-17,317.0)
-
kW-mo/yr
|
$(-5,650.0) | - | - | $24,284 | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $870 | $330 |
$30
2,345
kWh
|
$60
-
kW-mo/yr
|
- | - | $780 | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $790 | $400 |
$790
24,033
kWh
|
- | - | - | - | - | - | |
05 | 2.6218: Turn off equipment when not in use | $470 | - |
$470
18,757
kWh
|
- | - | - | - | - | - | |
06 | 3.7198: Reduce / eliminate use of disposable product | $1,220 | $110 | - | - | - |
$310
-
lb
|
- | - | $910 | |
07 | 3.5213: Reuse scrap printed paper for make-ready | $700 | $1,110 | - | - | - |
$2,000
-
lb
|
- | $(-1,300.0) | - | |
TOTAL RECOMMENDED | $8,002 | $2,570 |
$2,325
86,460
kWh
|
$(-15,657.0)
-
kW-mo/yr
|
$(-5,650.0) |
$2,310
-
lb
|
$780 | $22,984 | $910 | ||
TOTAL IMPLEMENTED | $2,830 | $1,840 |
$1,290
45,135
kWh
|
$60
-
kW-mo/yr
|
- |
$2,000
-
lb
|
$780 | $(-1,300.0) | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs