| Assessment Year | 1995 |
|---|---|
| Principal Product | Doors |
| NAICS |
n/a
|
| SIC | 2431: Millwork |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
254,000
ft2
|
| Annual Production | 300,000
pieces
|
| Production Hrs. Annual | 3,429
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $94,760 | 1,296,600 |
kWh
|
$0.073 |
| Natural Gas | $7,912 | 1,454 |
MMBtu
|
$5.44 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $10,350 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,360 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,390 | $2,000 |
$3,390
38,101
kWh
|
|
| 02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,840 | - |
$2,840
-
kWh
|
|
| 03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,600 | - |
$1,600
39,273
kWh
|
|
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $860 | $72 |
$860
9,672
kWh
|
|
| 05 | 2.7124: Make a practice of turning off lights when not needed | $720 | - |
$720
17,585
kWh
|
|
| 06 | 2.8121: Apply for tax-free status for energy purchases | $590 | $1,180 |
$590
-
kWh
|
|
| 07 | 2.4314: Use synthetic lubricant | $220 | - |
$220
2,345
kWh
|
|
| 08 | 2.7134: Use photocell controls | $130 | $40 |
$130
2,052
kWh
|
|
| TOTAL RECOMMENDED | $10,350 | $3,292 |
$10,350
109,028
kWh
|
||
| TOTAL IMPLEMENTED | $6,360 | $2,040 |
$6,360
40,153
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs