Assessment Year | 1995 |
---|---|
Principal Product | Steel weldments |
NAICS |
n/a
|
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $1 M to 5M |
# of Employees | 48 |
Plant Area |
46,000
ft2
|
Annual Production | 1,620
ton
|
Production Hrs. Annual | 4,328
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $86,113 | 1,125,733 |
kWh
|
$0.076 |
Natural Gas | $20,400 | 5,160 |
MMBtu
|
$3.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,825 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,985 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.8113: Purchase gas directly from a contract gas supplier | $5,600 | $2,105 | - | $5,600 | |
02 | 2.7145: Install skylights | $1,500 | $3,200 |
$1,500
57,444
kWh
|
- | |
03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,060 | - |
$1,060
33,118
kWh
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $780 | $124 |
$780
10,844
kWh
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $560 | $690 |
$560
20,516
kWh
|
- | |
06 | 2.6212: Turn off equipment during breaks, reduce operating time | $250 | - |
$250
9,379
kWh
|
- | |
07 | 2.4133: Use most efficient type of electric motors | $75 | $370 |
$75
1,172
kWh
|
- | |
TOTAL RECOMMENDED | $9,825 | $6,489 |
$4,225
132,473
kWh
|
$5,600 | ||
TOTAL IMPLEMENTED | $7,985 | $6,365 |
$2,385
88,511
kWh
|
$5,600 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs