ITAC Assessment: AM0246
ITAC logo
ITAC Assessment: AM0246
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1995
Principal Product Motor vehicle exhaust system parts
NAICS
n/a
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $10
M
to 50
M
# of Employees 260
Plant Area 146,000
ft2
Annual Production 4,660,000
pieces
Production Hrs. Annual 6,048
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $239,328 3,021,102
kWh
Natural Gas $5,179 1,115
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $11,977 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,118

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7124: Make a practice of turning off lights when not needed $3,553 - $3,553
50,703
kWh
02 2.7124: Make a practice of turning off lights when not needed $2,618 - $2,618
37,515
kWh
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,550 $500 $1,550
20,516
kWh
04 2.7124: Make a practice of turning off lights when not needed $1,340 - $1,340
19,050
kWh
05 2.6212: Turn off equipment during breaks, reduce operating time $1,210 - $1,210
17,292
kWh
06 2.7142: Utilize higher efficiency lamps and/or ballasts $950 - $950
11,430
kWh
07 2.4314: Use synthetic lubricant $456 - $456
6,155
kWh
08 2.3132: Recharge batteries on during off-peak demand periods $300 - $300
-
kWh
TOTAL RECOMMENDED $11,977 $500 $11,977
162,661
kWh
TOTAL IMPLEMENTED $5,118 $500 $5,118
69,461
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs