Assessment Year 1995
Principal Product Honing, Boring, Straightening and Sawing Steel Tubing
NAICS
n/a
SIC 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 47
Plant Area 150,000
ft2
Annual Production 0
units
Production Hrs. Annual 6,000
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $100,676 1,474,209
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $6,980 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $6,980

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.3212: Optimize plant power factor $5,560 $8,200 $5,560
-
kWh
02 2.4133: Use most efficient type of electric motors $510 $540 $510
8,499
kWh
03 2.7142: Utilize higher efficiency lamps and/or ballasts $375 $120 $375
4,103
kWh
04 2.7124: Make a practice of turning off lights when not needed $315 $124 $315
11,137
kWh
05 2.7124: Make a practice of turning off lights when not needed $220 $250 $220
4,982
kWh
TOTAL RECOMMENDED $6,980 $9,234 $6,980
28,721
kWh
TOTAL IMPLEMENTED $6,980 $9,234 $6,980
28,721
kWh
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs