Assessment Year | 1995 |
---|---|
Principal Product | Honing, Boring, Straightening and Sawing Steel Tubing |
NAICS |
n/a
|
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 47 |
Plant Area |
150,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $100,676 | 1,474,209 |
kWh
|
$0.068 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,980 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,980 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $5,560 | $8,200 |
$5,560
-
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $510 | $540 |
$510
8,499
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $375 | $120 |
$375
4,103
kWh
|
|
04 | 2.7124: Make a practice of turning off lights when not needed | $315 | $124 |
$315
11,137
kWh
|
|
05 | 2.7124: Make a practice of turning off lights when not needed | $220 | $250 |
$220
4,982
kWh
|
|
TOTAL RECOMMENDED | $6,980 | $9,234 |
$6,980
28,721
kWh
|
||
TOTAL IMPLEMENTED | $6,980 | $9,234 |
$6,980
28,721
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs