Assessment Year 1995
Principal Product Plastic produce bags
NAICS
n/a
SIC 2673: Plastics, Foil, and Coated Paper Bags
Sales Range $5
M
to 10
M
# of Employees 60
Plant Area 37,000
ft2
Annual Production 5,500,000
lb
Production Hrs. Annual 7,344
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $255,132 4,449,883
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $15,330 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $15,330

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Administrative Changes Savings
01 2.8114: Change rate schedules or other changes in utility service $6,230 - - $6,230
02 2.4231: Reduce the pressure of compressed air to the minimum required $3,860 $40 $3,860
83,822
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,340 $1,570 $1,340
27,843
kWh
-
04 2.7111: Reduce illumination to minimum necessary levels $870 $170 $870
18,464
kWh
-
05 2.3134: Shift from daytime to nighttime operation $780 - $780
-
kWh
-
06 2.2511: Insulate bare equipment $670 $835 $670
24,912
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $640 $1,960 $640
7,034
kWh
-
08 2.4314: Use synthetic lubricant $610 - $610
13,189
kWh
-
09 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $330 $500 $330
12,016
kWh
-
TOTAL RECOMMENDED $15,330 $5,075 $9,100
187,280
kWh
$6,230
TOTAL IMPLEMENTED $15,330 $5,075 $9,100
187,280
kWh
$6,230
Yearly Savings* Imp'd Cost* Electricity Usage Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs