Assessment Year | 1995 |
---|---|
Principal Product | Polyethylene bottles |
NAICS |
n/a
|
SIC | 3085: Plastics Bottles |
Sales Range | $10 M to 50M |
# of Employees | 190 |
Plant Area |
40,000
ft2
|
Annual Production | 110,000,000
pieces
|
Production Hrs. Annual | 8,712
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $860,304 | 16,941,970 |
kWh
|
$0.051 |
Natural Gas | $3,529 | 722 |
MMBtu
|
$4.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,059 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,429 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,270 | $1,000 |
$8,270
293,083
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $3,040 | $4,660 |
$3,040
67,995
kWh
|
|
03 | 2.7145: Install skylights | $630 | $1,140 |
$630
22,567
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,119 | $242 |
$1,119
24,326
kWh
|
|
TOTAL RECOMMENDED | $13,059 | $7,042 |
$13,059
407,971
kWh
|
||
TOTAL IMPLEMENTED | $12,429 | $5,902 |
$12,429
385,404
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs