Assessment Year | 1995 |
---|---|
Principal Product | Bricks |
NAICS |
n/a
|
SIC | 3251: Brick and Structural Clay Tile |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
233,600
ft2
|
Annual Production | 203,000
ton
|
Production Hrs. Annual | 4,732
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $526,256 | 9,207,503 |
kWh
|
$0.057 |
Natural Gas | $692,471 | 299,560 |
MMBtu
|
$2.31 |
Fuel Oil #2 | $49,000 | 9,100 |
MMBtu
|
$5.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,658 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,636 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Liquid (haz) Savings |
---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $5,136 | $5,690 |
$5,136
-
kWh
|
- | |
02 | 2.4314: Use synthetic lubricant | $2,520 | - |
$2,520
50,996
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $820 | $730 |
$820
16,413
kWh
|
- | |
04 | 2.7134: Use photocell controls | $500 | $125 |
$500
16,706
kWh
|
- | |
05 | 2.7124: Make a practice of turning off lights when not needed | $180 | - |
$180
6,155
kWh
|
- | |
06 | 3.8132: Use less toxic and volatile solvent substitutes | $502 | $1,200 | - |
$502
-
gal
|
|
TOTAL RECOMMENDED | $9,658 | $7,745 |
$9,156
90,270
kWh
|
$502
-
gal
|
||
TOTAL IMPLEMENTED | $6,636 | $6,545 |
$6,636
39,274
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Other Liquid (haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs